This sensor can be used to simultaneously measure airflow velocity or air volume flow and temperature. Optionally, the minimum, maximum, average or "hold" value can be displayed in addition to the measured value.
Here are some technical details of the TS 410 SDI:
Display 1: Air flow velocity
- Measuring range airflow: 0.00 to 20.00 m/s
- Resolution air flow: 0.01 m/s
- Accuracy airflow: ± (0.2 m/s + 2 % of measured value)
- Units airflow/volume flow: m/s, m³/s, m³/min, m³/h, l/min
Display 2: Temperature
- Measuring range temperature: 0 °C to +50 °C
- Resolution temperature: 0.1 °C
- Accuracy temperature: ± 0,7 °C (at v > 0,5 m/s)
- Units for temperature display: °C, °F
Sensor element
- Material: stainless steel
- Length / Ø: 210 mm / 6 mm
- Sensor handle Ambient conditions: 0 °C to +50 °C (measuring electronics in handle).
This sensor TS 410 SDI is connected using the TC 30 SDI connection cable!
The TS 410 SDI anemometer sensor is not only suitable for detecting weak points when verifying the air tightness of buildings (blower door), but also for distribution control of flow and temperature in ventilation and air conditioning systems.
Renovation companies also use it to check the capacity of their drying installations during insulation drying after water damage, because this sensor can be used to quickly and accurately determine whether the correct air flow is present at the relief openings to dry out the insulation layer!
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.220.250 | |
Air flow rate [m/s] | ||
Min. measuring range | Air flow rate [m/s] | 0 | |
Max. measuring range | Air flow rate [m/s] | 20 | |
Accuracy | Air flow rate [%] | 2 | |
Accuracy ± | Air flow rate [m/s] | 0.2 | |
Resolution | Air flow rate [m/s] | 0.01 | |
Measuring principle | Air flow rate | Hot film anemometer | |
Air temperature [°C] | ||
Min. measuring range | Air temperature [°C] | 0 | |
Max. measuring range | Air temperature [°C] | 50 | |
Resolution [°C] | 0.1 | |
Accuracy | Air temperature (text) | +0.7 °C (v > 0.5 m/s) | |
Interfaces / plug design | ||
Plug design | SDI connector | |
Dimensions of sensor element | ||
Length [mm] | 210 | |
Diameter Ø | Dimensions of sensor element [mm] | 6 | |
Material of sensor element | ||
Stainless steel | ||
Aluminium | ||
Composite | ||
Polycarbonate | ||
Other | ||
Material of handle | ||
Material | Plastics | |
Plastic/metal | ||
Metal | ||
Surrounding conditions (measuring electronics integrated in handle) | ||
Min. operating temperature [C] | 0 | |
Max. operating temperature [C] | 50 |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Air temperature [°F] | ||
Air flow rate [m/s] | ||
Air temperature [°C] | ||
Air volume flow [l/min] | ||
Air volume flow [m³/h] | ||
Air volume flow [m³/min] | ||
Air volume flow [m³/s] | ||
Functions and features | ||
Plastic probe | ||
Stainless steel probe |
standard equipment
optionally available
not available
Further information, guides, practial tips and capacity calculations
In our detailed product-catalogue websites you will find detailed information about the product, practical tips, guides for usage and, in some categories, capacity calculator for the perfect dimensioning.