Room air purifier TAC V+ II in white/black
Availability: Currently not in stock
Payment in installments
PayPal Buy Now Pay Later is not available to pay for subscriptions.
Room air purifier TAC V+ II in white/black
High-frequency zone air purifier for the efficient reduction of suspended matter and aerosol clouds in the immediate vicinity
The zone air purifier TAC V+ II reduces the residence time and intensity of aerosol and suspended matter clouds directly at the installation site
The zone air purifier TAC V+ II is an innovative solution for establishing clean air zones low in viruses and pollutants wherever they are needed - power connection is sufficient. Wherever this mobile air purifier is placed, it creates a "clean zone area" of up to 320 cubic meters in volume, flushed with clean, filtered clean air, depending on the required air exchange rate.
In this treatment zone, the ambient air remains largely free of germs, fine dust or other airborne microparticles, because the TAC V+ II enables large-volume intake of polluted room air with effective H14 high-performance filtration in accordance with EN 1822 (ISO 45H filter ISO 29463) and flexibly adjustable flushing of the zone, free of aerosol particles.
In combination with the integrated F7 pre-filter system, the Trotec H14 high-performance filter according to EN 1822 ensures reliable separation of airborne germs, viruses and of dust, bacteria, spores or microfibers from paper such as textiles.
Worldwide unique and only available from Trotec is the innovative combination of high-performance filter and decontamination technology:
The TAC V+ II has a thermal self-regeneration function of the H14 high-performance special filter, which automatically inactivates all viruses deposited in the filter at regular intervals and thus "decontaminates" the filter again to 100%.
In this way, the TAC V+ II significantly and safely reduces an airborne risk of infection in high-traffic public areas and ensures dust-free working conditions in dust-laden work zones:
- Protects customers, patients, guests and employees by significantly reducing the risk of infection .
- Protects employees from exposure to particulate matter in the workplace .
- Protects materials, electronics and machinery from contamination and dust-related malfunctions .
Some of many convincing equipment advantages of the TAC V+ II
Integrated silencer:As standard equipment, the TAC V+ II has an efficiency-increasing, dual intake air routing via integral silencer. This makes it ideally suited for noise-sensitive areas, such as schools, offices or practices.
Easy operation: The commissioning of the TAC V+ II requires only a few simple steps. In addition, the high-performance air purifier is equipped with an intuitive, convenient touch display that can be updated via USB.
Uniform clean air distribution: With its vertical directional effect, the specific lamella characteristic of the DualDecon blowout tower ensures uniform, zone-filling flushing with filtered clean air. By means of optionally available flowstop orifices, individual blow-out sides can also be blocked, for example in the case of wall-side blow-out direction.
Thermal filter decontamination: Worldwide unique and exclusive only to Trotec:
The TAC V+ II has an automatic thermal self-regeneration function of the H14-HEPA high-performance special filter according to EN 1822 ISO, which in regular intervals, all viruses deposited in the filter inactivated and thus the filter again to 100% "decontaminated".
Robust and mobile: Thanks to sturdy wheels and adjustable push handle, the robustly designed room air purifier is ideal for quickly changing the place of use. Simply set up, connect to the mains and start the air purification process.
Advantages for practice:
- Permanent air purification and virus filtering in zones with high public traffic or densely populated occupied zones (fine aerosols that contain infectious viruses such as. e.g., SARS-CoV, MERS-CoV or SARS-CoV-2/Covid-19 or influenza are filtered out with the class H14 filter according to EN 1822 ISO)
- Permanent air pollution control, virus and fine dust filtering in work zones with increased fine dust pollution .
- Unique in the world and exclusive only to Trotec: Automatic filter regeneration through thermal virus decontamination of the specially developed, heat-resistant high-performance HEPA filter of class H14 according to EN 1822 ISO with a separation efficiency of 99.995 % at a particle size of 0.1 to 0.2 μm
- "Clean-Zones-Areas": Establish safe occupied and working zones with virus-free filtered breathing air - individually dimensioned according to the number of devices and persons as well as the set air exchange rate .
- "Plug & Play" - set up, plug in, switch on, done. Room filtration independent of existing air conditioning and ventilation systems .
- Effective air filtration with F7 pre-filter and H14 HEPA main filter .
- Adjustable discharge directions via flowstop orifice for demand-based flooding of clean air into the desired clean air zones .
- Optimally matched system components for flexible applications in virus and dust protection .
- Easy operation: fully automatic, low-maintenance round-the-clock operation .
- Resource-saving: 100% environmentally friendly, no chemicals, no installation effort .
- High-quality materials and workmanship: "Made in Germany" - original Trotec manufacture, special virus filter with individual testing and test certificate .
- Low-investment: maximum profitability due to loss-free air purification directly at the installation site .
- Flexibly placeable: Always place the mobile TAC V+ II where it is needed .
Figures may show optional equipment or accessories that are not included in the basic price of the TAC V+ II.
Scope of delivery:
TAC V+ II air purifier
1 X F7 pre-filter
1 X H14 filter according to EN 1822 (ISO 45H filter ISO 29463)
Please note that the flowstop screen is not included in the delivery!
Caution! Only use original replacement filters from Trotec. Only these are suitably designed for your device,tested and heat-resistant. Cheap replicas usually do not achieve the specified filter values or guarantee the air volumes for which your device is designed. When using cheap replica filters to protect against viruses, there may be a health hazard. The heat-resistant filter is heated to very high temperatures during themode contamination, for which cheap replica filters are not designed. There is a fire hazard here! Therefore, for your own safety, use only original filters from Trotec.
Federal government and states promote investment in mobile air purifiers
.
Whether for schools, daycare centers, catering establishments, cultural workers or freelancers - to counteract the corona pandemic with technical solutions, the federal government and the states support investments in TAC V+ II high-performance air purifiers with several subsidy programs.
Customers from the catering industry: Take advantage of our exclusive partnership with METRO and Pentagast
METRO subsidizes the purchase of a TAC V+ II for restaurateurs under certain conditions
.
https://www.metro.de/service/pentagast/trotec
Pentagast as a sales partner offers a nationwide service network for professional advice, set-up, instruction and maintenance of your TAC V+ II
https://www.pentagast.de/angebot/hochleistungsluftreiniger
If you have any further product questions, please do not hesitate to contact us at the following number: 02452-962730
Technical data | ||
---|---|---|
General information | ||
Article number | 1.580.001.151 | |
Dust class | ||
as per DIN EN 1822 (ISO 45H filter ISO 29463) | H14 | |
as per DIN EN 779:2002 | F7 | |
Air flow rate | ||
Max. air volume flow [m³/h] | 2,100 | |
Suitable for rooms sized up to [m²/m³] with H14 filter class | 80 m² /200 m³ | |
Recommended amount of air for HighFlow filter with filter class H14 ≤ [m³/h] | 1,200 | |
Recommended amount of air for HighFlow filter with filter class H13 ≤ [m³/h]] | 2,100 | |
Electrical values | ||
Mains connection | 220 - 240 V, 50/60 Hz | |
Power consumption without thermal decontamination at 900 m³ / h air volume [kW] | 0.16 | |
Power consumption with thermal decontamination (60 min) [kW] | 1.25 | |
Nominal current consumption [A] | 5.5 | |
Recommended fusing [A] | 10 | |
Electric connection | ||
Connection plug | CEE 7/7, H07RN-F | |
Cable length [m] | 4 | |
Sound values | ||
Sound level in compliance with ISO 11203 | 29 – 50 dB | |
Depending on the configuration (sound protection caps, FlowExtender) | 29 - 50 dB(A) | |
Fan | ||
Radial | ||
axial | ||
stages | 7 | |
Protection class | IP20 | |
Dimensions | ||
Length (packaging excluded) [mm] | 690 | |
Width (packaging excluded) [mm] | 610 | |
Height (packaging excluded) [mm] | 1,300 | |
Weight | ||
(packaging excluded) [kg] | 89 |
Equipment, features and functions | ||
---|---|---|
Equipment | ||
Thermal filter decontamination | ||
Thermal filter regeneration | ||
Touchscreen | ||
Usage-related, sensor-controlled filter change indication of the F7 prefilter | ||
Usage-related, sensor-controlled filter change indication of the H14 main filter | ||
FlowMatic control | ||
Timer switch for the device is flexibly adjustable | ||
Timer switch for thermal decontamination is flexibly adjustable | ||
Operating hours counter | ||
Update of the control software via USB flash drive | ||
Language setting | ||
Key lock | ||
Silence mode | ||
Filter change indication | ||
Pre-filter | ||
Main filter | ||
Filter | ||
combination Hygienic areas (≥ 15 ACH) | F7 + H14 | |
Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] | 107 | |
Mobility | ||
Carry/transport handle(s) | ||
Trestle rollers/ fixed castors | ||
Non-marking rubber wheels/rollers | ||
Foot | ||
Protective bar at the control panel | ||
Full-rubber guide wheels | ||
Guiding wheels pneumatic tyres | ||
Stacking frame | ||
Forklift pockets | ||
Shock protection frame |
standard equipment
optionally available
not available









Proof of efficacy 128m³ TAC V+ / TAC M (DE)
Wirksamkeitsnachweis_VDI_EE4300_128m3.pdf (835 KB)

Proof of efficacy 267m³ TAC V+ / TAC M (DE)
Wirksamkeitsnachweis_VDI_EE4300_267m3.pdf (0.95 MB)

Operating manual for high-performance air purifier TAC BASIC (DE)
TRT-BA-TAC_BASIC-TC-001-DE.pdf (2.74 MB)

Operating manual for high-performance air purifier TAC BASIC (EN)
TRT-BA-TAC_BASIC-TC-001-EN.pdf (2.74 MB)

Operating manual for high-performance air purifier TAC BASIC (ES)
TRT-BA-TAC_BASIC-TC-001-ES.pdf (2.76 MB)

Operating manual for high-performance air purifier TAC BASIC (FR)
TRT-BA-TAC_BASIC-TC-001-FR.pdf (2.74 MB)

Operating manual for high-performance air purifier TAC BASIC (IT)
TRT-BA-TAC_BASIC-TC-001-IT.pdf (2.76 MB)

Operating manual for high-performance air purifier TAC BASIC (NL)
TRT-BA-TAC_BASIC-TC-001-NL.pdf (2.76 MB)

Operating manual for high-performance air purifier TAC BASIC (PL)
TRT-BA-TAC_BASIC-TC-001-PL.pdf (2.76 MB)

Operating manual for high-performance air purifier TAC BASIC (TR)
TRT-BA-TAC_BASIC-TC-001-TR.pdf (2.77 MB)

Operating manual for high-performance air purifier TAC ECO (DE)
TRT-BA-TAC_ECO-TC-002-DE.pdf (3.30 MB)

Operating manual for high-performance air purifier TAC ECO (EN)
TRT-BA-TAC_ECO-TC-002-EN.pdf (3.29 MB)

Operating manual for high-performance air purifier TAC ECO (ES)
TRT-BA-TAC_ECO-TC-002-ES.pdf (3.30 MB)

Operating manual for high-performance air purifier TAC ECO (FR)
TRT-BA-TAC_ECO-TC-002-FR.pdf (3.30 MB)

Operating manual for high-performance air purifier TAC ECO (IT)
TRT-BA-TAC_ECO-TC-002-IT.pdf (3.30 MB)

Operating manual for high-performance air purifier TAC ECO (NL)
TRT-BA-TAC_ECO-TC-002-NL.pdf (3.30 MB)

Operating manual for high-performance air purifier TAC ECO (PL)
TRT-BA-TAC_ECO-TC-002-PL.pdf (3.30 MB)

Operating manual for high-performance air purifier TAC ECO (TR)
TRT-BA-TAC_ECO-TC-002-TR.pdf (3.30 MB)

Operating manual for high-performance air purifier TAC V+ II / TAC M II (DE)
TRT-BA-TAC-V-II-TAC-M-II-TC-002-DE.pdf (4.46 MB)

Operating manual for high-performance air purifier TAC V+ II / TAC M II (EN)
TRT-BA-TAC-V-II-TAC-M-II-TC-002-EN.pdf (4.45 MB)

Operating manual for high-performance air purifier TAC V+ II / TAC M II (ES)
TRT-BA-TAC-V-II-TAC-M-II-TC-002-ES.pdf (4.45 MB)

Operating manual for high-performance air purifier TAC V+ II / TAC M II (FR)
TRT-BA-TAC-V-II-TAC-M-II-TC-002-FR.pdf (4.49 MB)

Operating manual for high-performance air purifier TAC V+ II / TAC M II (IT)
TRT-BA-TAC-V-II-TAC-M-II-TC-002-IT.pdf (4.45 MB)

Operating manual for high-performance air purifier TAC V+ II / TAC M II (NL)
TRT-BA-TAC-V-II-TAC-M-II-TC-002-NL.pdf (4.45 MB)

Operating manual for high-performance air purifier TAC V+ II / TAC M II (PL)
TRT-BA-TAC-V-II-TAC-M-II-TC-002-PL.pdf (4.46 MB)

Operating manual for high-performance air purifier TAC V+ II / TAC M II (TR)
TRT-BA-TAC-V-II-TAC-M-II-TC-002-TR.pdf (4.46 MB)

Declaration of conformity for high-performance air purifier TAC V+ (DE)
TRT-CE-TAC_V_-HS-001-DE.PDF (109 KB)

Declaration of conformity for high-performance air purifier TAC V+ (INT)
TRT-CE-TAC_V_-HS-001-EN.PDF (109 KB)

Study by the University of the Federal Armed Forces Munich: Can a safe school operation be guaranteed during the pandemic? (DE)
schulbetrieb-waehrend-der-pandemie.pdf (875 KB)
Brochures

TROTEC CASE STUDY: Effective aerosol and virus filtering of the room air at TÖNNIES (DE)
DE-Case_Study_Luftreinigung_Toennies-HS-001.pdf (1.85 MB)

TROTEC CASE STUDY: Effective aerosol and virus filtering of the room air at TÖNNIES (EN)
EN-Case_Study_Luftreinigung_Toennies-HS-001.pdf (1.07 MB)

TROTEC CASE STUDY: Effective aerosol and virus filtering of the room air at TÖNNIES (ES)
ES-Case_Study_Luftreinigung_Toennies-HS-001.pdf (1.07 MB)

TROTEC CASE STUDY: Effective aerosol and virus filtering of the room air at TÖNNIES (FR)
FR-Case_Study_Luftreinigung_Toennies-HS-001.pdf (1.07 MB)

TROTEC CASE STUDY: Effective aerosol and virus filtering of the room air at TÖNNIES (IT)
IT-Case_Study_Luftreinigung_Toennies-HS-001.pdf (1.08 MB)

TROTEC CASE STUDY: Effective aerosol and virus filtering of the room air at TÖNNIES (NL)
NL-Case_Study_Luftreinigung_Toennies-HS-001.pdf (1.06 MB)

TROTEC CASE STUDY: Effective aerosol and virus filtering of the room air at TÖNNIES (PL)
PL-Case_Study_Luftreinigung_Toennies-HS-001.pdf (1.06 MB)
Specification texts