Room air purifier TAC V+ stainless steel
Availability: Immediately available
Payment in installments
PayPal Buy Now Pay Later is not available to pay for subscriptions.
Room air purifier TAC V+ stainless steel
High-frequency zone air purifier for efficient reduction of suspended particles and aerosol clouds in the direct installation environment
The zone air purifier TAC V+ reduces the dwell time and intensity of aerosol and suspended matter clouds directly at the installation site
The zone air purifier TAC V+ is an innovative solution for establishing clean air zones low in viruses and pollutants wherever they are needed - power supply is sufficient. Wherever this mobile air purifier is placed, it creates a "clean zone area" of up to 320 cubic metres volume flushed with clean, filtered clean air, depending on the required air exchange rate.
In this treatment zone, the ambient air remains largely free of germs, fine dust or other airborne micro-particles, because the TAC V+ enables the large-volume intake of contaminated room air with effective H14-HEPA high-performance filtration and flexibly adjustable flushing of the zone, free of aerosol particles.
In combination with the integrated F7 pre-filter system, the Trotec H14-HEPA high-performance filter guarantees reliable separation of airborne germs, viruses and of dust, bacteria, spores or microfibres from paper such as textiles.
Stainless steel version for hygiene-sensitive areas of the food industry
Especially for use in meat processing and food production, the TAC V+ high-performance air cleaner is optionally available in a stainless steel version, which is ideal for use in areas with specific hygiene requirements or particularly reactive air environments.
The stainless steel housing is easy to clean and made of the material 1.4301, which has a very high corrosion resistance and is particularly resistant to various chemical solutions.
Infectious aerosols - risk factor for the meat industry
Many experts agree that in the case of corona outbreaks in the meat industry, it is mainly the low temperatures required for meat cooling as well as aerosols, in which substances are transferred via the air, that can be the cause of rapid virus spread.
As a result, infectious aerosol particles sometimes float for up to several hours in the room air in the cutting area, which has cooled to 6 to 10 °C, due to their small size. They would be permanently moved around in the room by the ventilation system - and thus continuously inhaled! This finding coincides with other studies, which also suggest that viruses may be emitted into the environment in the form of aerosol clouds, especially when speaking, and may remain in the air for hours.
The problem is in the air, its solution also
If virus-carrying aerosols are suspended in the ambient air of meat-cutting areas or other working environments of meat-processing plants, there is an increased risk of infection. Viruses do not adhere to distance rules and also easily overcome physical barriers such as partition walls. If the ambient air can be kept free of viruses, the aerogenic risk of infection is also reduced.
Play it safe with high-frequency air purification
Trotec promotes aerosol control in indoor air as a decisive measure right from the start and, as the first address for professional air treatment solutions, can therefore also offer you the first highly effective air cleaning device with high-performance air filters and integrated virus decontamination!
Virus-free air reduces the aerogenic risk of infection to zero
If the room air can be kept largely free of germs and viruses, then the aerogenic risk of infection in endangered work zones in the meat and food industry is also minimized.
Our high-frequency air purifiers such as the TAC V+ were developed precisely for this task, because they effectively and quickly reduce the dwell time and intensity of aerosol and suspended matter clouds in closed rooms, thus creating an environment with greatly reduced risk of infection for all employees.
Exterminate aerosol clouds within minutes via high-performance air filtration
At the installation site, the mobile high-frequency air purifier creates a clean "clean zone area" flushed with virus-filtered clean air. In this zone, the ambient air remains largely free of airborne germs and viruses, because the TAC V+ enables the large-volume intake of contaminated room air with effective H14-HEPA high-performance air filtration and a flexibly adjustable zone flushing with virus-filtered clean air, free of aerosol particles.
Even a downstream supply of this room air to existing ventilation systems for cooling and dehumidifying the air no longer poses a risk of virus spreading, because if the supplied air has already been virus-filtered, no more viruses can be spread via air conditioning systems.
High-performance air cleaning works exactly where the greatest danger lurks
In the meat industry, the coronavirus spreads mainly via the air in the room. The reason for this is the air conditioning customary in the industry. The room air in the production areas is usually only cooled down and dehumidified, but in recirculation mode - no fresh air is supplied. In addition, most plants do not have high-performance filtration. As soon as infectious viruses are present at only one point in the room, then circulating air conditioning and the lack of virus filtration quickly cause a room-filling distribution of infectious viruses through the air in the entire work area.
Without virus no virus spreading, in principle quite simple
If it were possible to keep the air in the room free of viruses, the aerogenic risk of infection would also be minimized. Even a downstream cooling, dehumidification and re-introduction of this air would then be risk-free, because the viruses would already have been filtered out of the air beforehand.
Trotec high-frequency air cleaners such as the TAC V+ have been developed precisely for this task, because they effectively and quickly reduce the dwell time and intensity of aerosol and suspended matter clouds in closed rooms, thus creating a working environment with a greatly reduced risk of infection for all employees.
High-performance air filtration enables virus-free work zones
The mobile air purifier TAC V+ creates a clean "clean zone area" directly at its installation site, flushed with virus-filtered clean air. In this zone, the ambient air remains largely free of airborne germs and viruses, because the TAC V+ enables the large-volume intake of contaminated room air with effective H14-HEPA high-performance air filtration and a flexibly adjustable zone flushing with virus-filtered clean air, free of aerosol particles.
This clean air can then also be fed safely into the company's internal ventilation system for cooling and dehumidification. Since the air supplied in this way is already practically virus-free, the dehumidified cooling air can be reintroduced into the room without risk.
Effective against bacteria and virus conglomerates
Trotec high-frequency air cleaners are equipped with high-performance HEPA filters of class H14, which separate more than 99.995% of all fine suspended particles larger than 0.1 µm and have a transmission factor of only 0.005%. Or to put it differently: Out of 100,000 particles, a maximum of only five pass through the H14 high-performance air filter.
Thanks to this first-class feature, such high-performance filters are also used in operating theatres for clean air production and in comparably hygiene-sensitive areas. These are the best prerequisites for reliably keeping room and breathing air free of viruses in slaughterhouses, cutting plants and other closely occupied working areas of the meat processing industry in times of rampant epidemics.
Well-known virus strains such as SARS-CoV, MERS-CoV or Covid-19 have a particle size of 0.005 µm to 0.1 µm. Usually combined with other particles, such as saliva, suspended solids etc., they form conglomerates with a size between 0.4 µm and 0.5 µm. These conglomerates are also called germs and are reliably separated by the Trotec H14 high-performance air purification filters.
Neutralize virulent aerosol clouds directly in the working zone
The TAC V+ can effectively clear the ambient air in employees' work areas of virus-carrying aerosols. This high-frequency air purifier filters the aerosols out of the room air with a high recirculation rate in a very short time and, as a result, permanently flushes the areas with large quantities of virus-free room air, which significantly reduces the risk of infection in the treated zones.
Worldwide unique filter decontamination
This clean air performance is made possible by a synchronous system of efficient pre-filtration and final HEPA filtration using an integrated Trotec H14-HEPA high-performance air filter in a special heat-resistant design. The special filter used in the TAC V+ not only reliably retains 99.995% of all aerosol particles larger than 0.1 µm, which means that out of 100,000 particles a maximum of only five pass through the H14 filter, as is standard practice in high-performance filtration in operating theatres, for example - unlike such applications, however, the H14 high-performance air filter from Trotec in the TAC V+ is additionally heated cyclically, which inactivates all the viruses separated in the filter and thus "decontaminates" the filter 100% again.
This thermal self-regeneration function of the H14 special filter is unique worldwide and only available from Trotec! Thanks to this unique combination of filter and decontamination technology, the TAC V+ safely reduces the airborne risk of infection in all vulnerable work zones - ideal for slaughterhouses and other critical meat processing production areas.
Effective HEPA filtering according to the highest quality requirements, which are obligatory for bacteria and virus filtering:
- Each H14 high performance air filter is individually tested and provided with its own serial number
- The test report is enclosed with every H14 high performance air filter in duplicate as a certificate
- The original test certificate can be filed in the documents - and the copy can be attached to the air purifier as required
- H14-HEPA high performance air filters from Trotec are tested according to EN 1822 and EN 60335-2-69
Some of many convincing equipment advantages of the TAC V+
Simple operation: Commissioning the TAC V+ requires only a few steps. Timer, operating hours counter, filter level warning indicators and operating switches are installed in shockproof design.
Uniform distribution of clean air: The specific lamellar characteristics of the DualDecon blow-out tower with its vertical directivity ensure an even, zone-filling flushing with filtered clean air. Individual discharge sides can also be blocked by means of optionally available flow-stop orifices, e.g. when the air is discharged from the wall.
Thermal filter decontamination: Unique worldwide and exclusive only at Trotec:
The TAC V+ has an automatic thermal self-regeneration function of the HEPA high-performance special filter, which inactivates all viruses separated in the filter at regular intervals and thus "decontaminates" the filter 100%.
Robust and mobile: Thanks to stable wheels and adjustable push handle, the robustly constructed air purifier is ideal for quickly changing the place of use. Simply set it up, connect it to the power supply and start the air cleaning process.
Advantages for the practice:
- Permanent air pollution control and virus filtering in zones with high public traffic or densely populated zones
- Permanent air pollution control, virus and fine dust filtering in working zones with increased fine dust pollution
- Unique in the world and exclusive to Trotec: automatic filter regeneration through thermal virus decontamination of the specially developed, heat-resistant, high-performance HEPA filter of class H14 with a separation efficiency of 99.995 % at a particle size of 0.1 to 0.2 μm
- "Clean-Zones-Areas": Establish safe stay and work zones with virus-free filtered breathing air - individually dimensioned according to the number of devices and persons and the set air exchange rate
- „Plug & Play“ – Set it up, plug it in, switch it on, done. Room filtration independent of existing air conditioning and ventilation systems
- Effective air filtration with F7 prefilter and H14-HEPA main filter
- Blow-out directions adjustable via flow-stop orifice for demand-oriented flooding of the clean air into the desired clean air zones
- Optimally matched system components for flexible applications in the areas of virus and dust protection
- Simple operation: Fully automatic, low-maintenance round-the-clock operation
- Saving resources: 100 % environmentally friendly, no chemicals, no installation effort
- High-quality materials and workmanship: "Made in Germany" - original Trotec manufacture, virus special filter with individual testing and test certificate
- Investment protection: Maximum profitability through loss-free air cleaning directly at the installation site
- Flexible positioning: Always place the mobile TAC V+ where it is needed
Illustrations may show optional equipment or accessories that are not included in the basic price of the TAC V+.
Scope of delivery:
TAC V+ Air purifier
1 x F7 Prefilter
1 X H14 HEPA filter
Please note that the flowstop orifice is not included in the delivery!
Technical data | ||
---|---|---|
General information | ||
Article number | 1.580.000.154 | |
Dust class | ||
as per DIN EN 1822 (ISO 45H filter ISO 29463) | H14 | |
as per DIN EN 779:2002 | F7 | |
Air flow rate | ||
Suitable for rooms sized up to [m²/m³] with H14 filter class | 80 m² /200 m³ | |
Max. air volume flow [m³/h] | 2,200 | |
Recommended amount of air for HighFlow filter with filter class H14 ≤ [m³/h] | 1,200 | |
Recommended amount of air for HighFlow filter with filter class H13 ≤ [m³/h]] | 1,800 | |
Recommended amount of air for Ultra HighFlow filter with filter class H14 ≤ [m³/h] | 2,000 | |
Recommended amount of air for Ultra HighFlow filter with filter class H13 ≤ [m³/h] | 2,200 | |
Electrical values | ||
Mains connection | 220 - 240 V, 50/60 Hz | |
Power consumption without thermal decontamination at 900 m³ / h air volume [kW] | 0.16 | |
Power consumption with thermal decontamination (60 min) [kW] | 2.5 | |
Nominal current consumption [A] | 11.3 | |
Recommended fusing [A] | 13 | |
Electric connection | ||
Connection plug | CEE 7/7, H07RN-F | |
Cable length [m] | 4 | |
Sound values | ||
with sound protection hood - Distance 1 m | 33 - 64 dB(A) | |
with sound protection hood and Ultra HighFlow filter - Distance 1 m | 33 - 62 dB(A) | |
Fan | ||
Radial | ||
axial | ||
stages | 7 | |
Protection class | IP23 | |
Dimensions | ||
Length (packaging excluded) [mm] | 690 | |
Width (packaging excluded) [mm] | 610 | |
Height (packaging excluded) [mm] | 1,300 | |
Weight | ||
(packaging excluded) [kg] | 89 |
Equipment, features and functions | ||
---|---|---|
Equipment | ||
Thermal filter decontamination | ||
Thermal filter regeneration | ||
Touchscreen | ||
Usage-related, sensor-controlled filter change indication of the F7 prefilter | ||
Usage-related, sensor-controlled filter change indication of the H14 main filter | ||
FlowMatic control | ||
Timer switch for the device is flexibly adjustable | ||
Timer switch for thermal decontamination is flexibly adjustable | ||
Operating hours counter | ||
Update of the control software via USB flash drive | ||
Language setting | ||
Key lock | ||
Silence mode | ||
sound protection hood | ||
Flowstop shutters | ||
Hose adapter | ||
Manipulation protection | ||
Filter change indication | ||
Pre-filter | ||
Main filter | ||
Filter | ||
combination Hygienic areas (≥ 15 ACH) | F7 + H14 | |
Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] | 107 | |
Mobility | ||
Carry/transport handle(s) | ||
Trestle rollers/ fixed castors | ||
Non-marking rubber wheels/rollers | ||
Foot | ||
Protective bar at the control panel | ||
Full-rubber guide wheels | ||
Guiding wheels pneumatic tyres | ||
Stacking frame | ||
Forklift pockets | ||
Shock protection frame |
standard equipment
optionally available