IDE 80 Oil Fired Indirect Heater
Availability: Currently not in stock
IDE 80 Indirect Oil Heater
The IDE 80 Indirect Oil Heater with a nominal heat output of 80 kW (68,800 kcal) and an air flow rate of 2000 m³/h. The consumption comes to maximum 7.4 litres of oil per hour.
The Oil Heater of the IDE series are budget saving solutions with solid technology for typical standard heating tasks with direct warmth on site.
All oil fired indirect IDE devices take place with help of a Danfoss® injection pump. As well, these models have an easy reachable fuel filter on the outside.
For a desired temperature adjustment all IDE devices have an integrated thermostat with a dual display for set value and actual value. If the temperature should be measured and controlled at a place with a distance of 25 meters away from the heater, you can use the optionally available extern thermostat.
The fuel level of the integrated fuel tank can be read on the fuel level display.
Benefits in practise:
- Very economical solution for standard oil heaters
- Integrated fuel tank with fuel level display
- Electronic flame safeguard
- Overheating protection
- Stainless steel fire combustion chamber
- Integrated thermostat with a dual display for set value and actual value
- Connection for external thermostat
Some technical details of the IDE 80:
- Heating function: indirect
- Air flow rate: 2000 m³/h
- Nominal heat output: 80 kW (68,800 kcal)
- Temperature increase ∆T: 105 °C
- Input voltage: 230 V / 50 Hz
- Current consumption: 3,68 A
- Fuel consumption per hour max.: 7.4 l
- Thermostat: integrated
- Fuel supply: Danfoss® injection pump
- Flue connection Ø: 150 mm
- Sound level (distance 1 m): 85 dB (A)
- Tank capacity: 68 l
- Dimensions l x w x h: 1334 x 574 x 1030 mm
- Weight: 59.4 kg
Technical data | ||
---|---|---|
General information | ||
Article number | 1.430.000.240 | |
Functional principle | ||
Method of heating indirect | ||
Oil | ||
Method of heating direct | ||
Air flow rate | ||
Level Max. [m³/h] | 2,000 | |
Fan | ||
axial | ||
Radial | ||
Nominal heat output | ||
Level Max. [kW] | 80 | |
Level Max. [kcal] | 68,800 | |
Temperature increase | ||
Level Max. [°C] | 105 | |
Electrical values | ||
Mains connection | 230 V/50 Hz | |
Current consumption [A] | 3.3 | |
Power input [kW] | 0.9 | |
Heating capacity [kW] | 80 | |
Electric connection | ||
Cable length [m] | 1.2 | |
Operation | ||
Internal thermostat | ||
Overheating protection | ||
Connection for external thermostat | ||
Temperature indication | ||
Fuel feed | ||
Fuel feed | Danfoss pump | |
Fuel filter | ||
Available | ||
Oil consumption | ||
Level Max. [l/h] | 7.6 | |
Tank contents | ||
Content in [l] | 68 | |
Hose connection | ||
Diameter | Hose connection [mm] | 400 | |
Chimney connection | ||
Available | ||
Diameter | Chimney connection [mm] | 150 | |
Sound values | ||
Distance 1 m [dB(A)] | 80 | |
Suitable fuels | ||
Diesel | ||
EL fuel oil | ||
Low-sulphur EL fuel oil | ||
Kerosene | ||
Dimensions | ||
Length (packaging excluded) [mm] | 1,370 | |
Width (packaging excluded) [mm] | 560 | |
Height (packaging excluded) [mm] | 995 | |
Weight | ||
(packaging excluded) [kg] | 59 |
Equipment, features and functions | ||
---|---|---|
Mobility | ||
Plastic wheels | ||
Carry/transport handle(s) | ||
Rubber-tyred metal wheels | ||
Forklift | ||
Crane | ||
Housing design | ||
Steel |
standard equipment
optionally available
not available







Ratgeber Praxiswissen Profi-Beheizung (DE)
TRT-Ratgeber-Profi-Beheizung-HS-DE.pdf (3.98 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (CS)
TRT-BA-IDE20-30-50-60-80-TC-008-CS.pdf (3.53 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (DE)
TRT-BA-IDE20-30-50-60-80-TC-008-DE.pdf (3.53 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (EN)
TRT-BA-IDE20-30-50-60-80-TC-008-EN.pdf (3.52 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (FR)
TRT-BA-IDE20-30-50-60-80-TC-008-FR.pdf (3.53 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (HR)
TRT-BA-IDE20-30-50-60-80-TC-008-HR.pdf (3.52 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (IT)
TRT-BA-IDE20-30-50-60-80-TC-008-IT.pdf (3.53 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (NL)
TRT-BA-IDE20-30-50-60-80-TC-008-NL.pdf (3.53 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (PL)
TRT-BA-IDE20-30-50-60-80-TC-008-PL.pdf (3.53 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (SK)
TRT-BA-IDE20-30-50-60-80-TC-008-SK.pdf (3.53 MB)

Operating manual for oil heating units IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 (SL)
TRT-BA-IDE20-30-50-60-80-TC-008-SL.pdf (3.52 MB)
Further information, guides, practial tips and capacity calculations
In our detailed product-catalogue websites you will find detailed information about the product, practical tips, guides for usage and, in some categories, capacity calculator for the perfect dimensioning.